1. Project Overview
Project Title | Development of outdoor misting system to prevent heat-related illnesses |
Theme | |
Period | 2017.04 - 2020.03 |
Program | Industry-Academia Collaboration |
Lead Labs | |
Funding Agency | Panasonic |
Tags |
2. Objectives
โข
Evaluate thermal sensations and thermal comfort in a mist spraying environment
โข
Confirm cooling effects by measuring environmental factors:
โฆ
Air temperature
โฆ
Relative humidity
โฆ
Mean Radiant Temperature (MRT)
โฆ
Air velocity
โข
Develop and validate a physiological human model considering mist wettedness
(Comparison of skin temperature in/outside the mist zone)
3. Methodology
โข
Field surveys before and after mist exposure
โข
Number of subjects: 1,110
โข
Comparative analysis:
โฆ
Subjective votes (mTSV & CSV)
โฆ
Objective environmental measurements
โฆ
Skin temperature trends (0โ10 min outdoor vs 10โ20 min mist zone)
4. Key Findings
โข
Thermal Sensation:
โฆ
โHotโ reduced from 98% โ 33% after mist exposure
โข
Thermal Comfort:
โฆ
โDiscomfortโ reduced from 82% โ 14%
โข
Environmental Effects:
โฆ
Air temperature โ 3.6ยฐC
โฆ
MRT โ 1.0ยฐC
โฆ
Humidity โ 15.9%
โข
Human Model:
โฆ
Developed a 3-node thermal model with/without mist wettedness
โฆ
Accurately estimated thermal state changes via skin temp analysis